What is the procedure for 2010ECL signal monitor ATSI test?

This article discusses the procedure for performing an EDI 2010ECL signal monitor ATSI test.

Procedure

  1. Download and install PCMT-8800 Test Manager software.
  2. Open PCMT-8800 Test Manager.
  3. Go to “Monitor Info” and enter signal monitor details.
  4. Go to "Test Setup" and set:
    1. Test Standard Caltrans = Model 2010
    2. Monitor Type = 18 Channel
    3. Test Type = Certification
    4. Test Laps = One
  5. Open MonitorKey software and set the following:
    1. Top dip switch: 1,4,6,7 “on”
      1. All others “off” —> RF 2010, GY ENABLE, LEDguard, RF

        SSM

    2. Middle dip switch: all “on” (SSM on for all channels)
    3. Bottom dip switch: all “on” (SSM on for all channels)
    4. WD Enable: “on”
  6. Insert “Regular Test Card” with all diodes soldered in.
  7. Start test.
    1. Make sure you reset monitor for five seconds after setting switches).
    2. Tester will “beep” when complete.

Did this answer your question? Thanks for the feedback There was a problem submitting your feedback. Please try again later.