[EDI] How do I update the 2010ECLip signal monitor firmware using ECcom?
This video demonstrates how to update the firmware on an EDI 2010ECL monitor using ECCom software.
1. Prepare the monitor
- Power up the 2010ECL monitor. Performing the update outside an active intersection is recommended.
- Connect the Ethernet cable.
- Confirm the monitor is powered on and ready.
2. Install and connect using ECCom
- Download the ECCom software from our article here.
- Open ECCom and go to Setup → Settings → LAN.
- Select Search to locate the monitor.
- Select the monitor and click Test to verify communication and confirm the model is 2010ECL.
3. Obtain the firmware
- In ECCom, go to Windows → Help → Firmware Update.
- Remove the program card when prompted, then click OK.
- Request the latest firmware from EDI.
- Extract the emailed ZIP file and locate the HEX firmware file.
- Copy the HEX file to a local directory (e.g.,
C:\Temp) to avoid network interruptions.
4. Load the firmware
- Browse to the directory containing the HEX file.
- Select the firmware file and click Open.
- Start the update.
- Confirm the monitor's COM indicator flashes during the transfer.
- Allow approximately 5–10 minutes for the update to complete.
5. Restart and verify
- Wait for ECCom to confirm the firmware update is complete.
- Power-cycle the monitor when prompted.
- Reconnect through ECCom using LAN Search.
- Click Test and verify the updated firmware version.
To download the latest firmware for your monitor, please see our support article here.