Caltrans Comparison Guide - 210 vs 2010ECL vs 2018ECL vs 2018KCL Signal Monitors

Basic Functionality

Feature 210 (Caltrans) 2010ECL 2018ECL 2018KCL
Channels 16 16 18 18
Compatibility TEES Standard TEES Standard, Advanced Controllers (170, 2070) TEES Standard, Advanced Controllers (170, 2070) TEES Standard, Advanced Controllers (170, 2070)
Conflict Monitoring Yes Yes Yes Yes
24 VDC Monitoring Yes Yes Yes Yes
Watchdog Timer (WDT) Monitoring Yes Yes Yes Yes

Hardware Features

Feature 210 (Caltrans) 2010ECL 2018ECL 2018KCL
Microprocessor-based Yes Yes (dual) Yes (dual) Yes (dual)
Non-Volatile Fault Memory Yes Yes Yes Yes
RMS Signal Detection Yes Yes Yes Yes
Flash Memory For Updates No Yes Yes Yes
Internal MPU Watchdog Yes Yes Yes Yes
Datakey Configuration No No No Yes
LED Field Signal Monitoring (LEDguard®) No Yes Yes Yes

Fault Monitoring Enhancements

Feature 210 (Caltrans) 2010ECL 2018ECL 2018KCL
Red Failure Monitoring No Yes Yes Yes
Dual Indication Monitoring No Yes Yes Yes
Clearance Monitoring No Yes Yes Yes
Brown-Out Detection Yes Yes Yes Yes
Recurrent Pulse Detection No Yes Yes Yes
Flashing Yellow Arrow (FYA) Support No Yes Yes Yes

Communication and Interface

Feature 210 (Caltrans) 2010ECL 2018ECL 2018KCL
Serial Port (EIA-232) No Yes Yes Yes
Ethernet (IP Models) No

Yes

(2010ECLip)

Yes

(2010ECLip)

Yes

(2010ECLip)

Diagnostic Display Mode Basic Advanced Advanced Advanced
Event Logging No Yes Yes Yes

Installation and Programming

Feature 210 (Caltrans) 2010ECL 2018ECL 2018KCL
Program Card-Based Configuration Yes Yes Yes

No

(Uses Datakey)

DIP Switch Configuration Yes Yes Yes

No

(Uses Datakey)

Configuration Change Monitoring No Yes Yes Yes
Remote Configuration Support No Yes Yes Yes

Key Differences For Transitioning from 210 Monitor

  • Enhanced Fault Monitoring: The 2010, 2018, and 2018KCL models provide Red Failure, Dual Indication, and Clearance monitoring, which are absent in the 210.
  • Advanced Communication: The newer models (2010ECL, 2018ECL, and 2018KCL) offer serial communication (EIA-232) and Ethernet options.
  • More Precise Monitoring: RMS-based voltage detection improves accuracy.
  • Event Logging & Diagnostics: The newer models provide improved fault recording for better troubleshooting.
  • Datakey Programming (2018KCL Only): Replaces traditional program cards and DIP switches with an electronic memory key for a more straightforward configuration.
  • Compatibility & Expandability: The 2018ECL and 2018KCL provide 18-channel monitoring for expanded traffic control needs

For more information on features between the signal monitors, please see our article here.